Overview

This OEM single-pole contactor (part number 1050699) is the primary switching relay for the ICP Tempstar/Heil YH036GC outdoor unit. On a thermostat call, the 24V coil energizes and closes the contacts to deliver line voltage to the compressor and condenser fan motor. Rated at 25 amps with a 24V coil, it handles the full inrush and running load of the outdoor equipment. Contactors fail frequently because the contacts arc and pit on every cycle. A bad contactor presents as no cooling or heat-pump operation, loud chattering at the unit, or a coil that buzzes but never pulls the contacts closed.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand ICP (Tempstar / Heil)
Rating 25 Amps
Coil Voltage 24V
Poles 1
Fitment OEM

Compatibility

Fits the ICP Tempstar/Heil YH036GC condensing unit and other matching outdoor units using a 1-pole 25A definite-purpose contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the service panel on the condensing unit.
  3. Document — Photograph all line, load, and 24V coil wire connections before disconnecting.
  4. Remove — Transfer wires one at a time to the new contactor, or label and disconnect, then unscrew the old contactor from the base.
  5. Install — Mount the new contactor and reconnect line, load, and coil leads exactly per your photo.
  6. Test — Restore power and verify the coil pulls in cleanly and quietly on a call.

Signs You Need a Replacement

  • Outdoor unit will not start on a cooling or heat-pump call
  • Loud buzzing or chattering at the contactor
  • Pitted, burnt, or welded contacts
  • Compressor and fan run nonstop with no thermostat call (stuck closed)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YH036GC — 1-Pole 25A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YH036GC — 1-Pole 25A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YH036GC — 1-Pole 25A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.