Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for YG048G — 1-Pole 35A 24V Coil | Ships Today
ICP

ICP Contactor for YG048G — 1-Pole 35A 24V Coil | Ships Today

SKU: 1050839 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM single-pole definite purpose contactor (Part No. 1050839) for the ICP / Tempstar / Heil YG048G heat pump condensing unit. The contactor is the high-voltage switch that energizes the compressor and condenser fan motor whenever the 24V control circuit calls for cooling or heat-pump operation. It is rated for 35 amps with a 24-volt coil. When the thermostat closes the circuit, the coil pulls the contacts together to deliver line voltage to the compressor; when the call ends, the spring opens the contacts. Burnt, pitted, or chattering contacts are one of the most common reasons an outdoor unit fails to start, hums, or trips a breaker.

Specifications

Spec Value
Part Number 1050839
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Tempstar / Heil / Comfortmaker
Contact Rating 35 Amps
Coil Voltage 24 VAC
Poles 1
Fits Model YG048G

Compatibility

Engineered for the ICP/Tempstar/Heil YG048G heat pump and shared across many ICP-family condensing units and heat pumps that use a 35A 24V single-pole contactor. Always confirm the existing contactor's amp rating, coil voltage, and pole count against your unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the condensing unit's electrical access panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting anything.
  4. Remove — Label and disconnect the wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo (L1/L2 line, T1/T2 to compressor and fan, 24V to the coil terminals).
  6. Test — Restore power and confirm the contactor pulls in cleanly on a cooling call with no chatter.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan won't start
  • Visible pitting, burning, or melted plastic on the contacts
  • Buzzing or chattering when the system calls for cooling
  • Contacts stick closed and the unit won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG048G — 1-Pole 35A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG048G — 1-Pole 35A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG048G — 1-Pole 35A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.