Overview

This OEM single-pole definite-purpose contactor (part number 1172472) is the electrically-controlled switch that energizes the compressor and condenser fan in your ICP/Tempstar/Heil WPH4244000RKA1 heat pump. When the thermostat calls for cooling or heating, the 24V control circuit pulls in the contactor coil, closing a 30-amp set of contacts that delivers line voltage to the outdoor unit. This version includes a shunt for proper current distribution. Contactors are one of the most common failure points in outdoor units because the contacts arc and pit every time they open and close. Symptoms of failure include a unit that won't start, a chattering or buzzing outdoor unit, contacts that weld shut so the compressor never shuts off, or visible burning/pitting on the contact surfaces.

Specifications

Spec Value
Part Number 1172472
Type 1-Pole, with shunt
Brand ICP / Tempstar / Heil
Contact Rating 30A
Coil Voltage 24V

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WPH4244000RKA1 heat pump and compatible packaged and split systems that use a 1-pole 30A 24V contactor. Always confirm the original part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter at the contactor terminals.
  2. Access — Remove the outdoor unit service panel.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and remove the line, load, and 24V coil wires, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly as photographed.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start
  • Contacts are burned, pitted, or welded together
  • Compressor runs continuously and won't shut off
  • Chattering noise from the contactor when the thermostat calls

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPH4244000RKA1 — 1-Pole 30A 24V w/Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPH4244000RKA1 — 1-Pole 30A 24V w/Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPH4244000RKA1 — 1-Pole 30A 24V w/Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online