Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for WPG4604115LKA1 — 1-Pole 40A 24V Coil | Ships Today
ICP

ICP Contactor for WPG4604115LKA1 — 1-Pole 40A 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part 1173690) rated 40 amps with a 24V coil is the main switching relay for the ICP Tempstar Heil WPG4604115LKA1 packaged unit. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the contacts closed to deliver line voltage to the compressor and condenser fan motor. As a high-current switching component, contactors wear out from arcing and pitting on the contacts over thousands of cycles. A failing contactor causes hard starts, chattering, or a complete failure to energize the outdoor unit. Replacing it is one of the most common and effective HVAC service repairs.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 1 (single-pole)
Rating 40 A
Coil Voltage 24 V
Fitment OEM direct replacement

Compatibility

Built for the ICP Tempstar Heil WPG4604115LKA1 packaged unit and related ICP-family equipment using a 1-pole 40A 24V-coil contactor. Confirm pole count, amp rating, coil voltage, and the 1173690 part number before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the electrical/service panel to reach the contactor.
  3. Document — Photograph every line, load, and 24V coil connection before disconnecting.
  4. Remove — Transfer wires one at a time, or move them all after photographing, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or chatters but won't start
  • Pitted, burnt, or welded contacts
  • Compressor and condenser fan fail to energize on a cooling call
  • Buzzing coil or intermittent cooling operation

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4604115LKA1 — 1-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4604115LKA1 — 1-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4604115LKA1 — 1-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online