OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This genuine OEM single-pole contactor (part #1173690) is the primary switching relay for the ICP/Tempstar/Heil WPG4484090RKB1 packaged unit. Rated at 40 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V coil receives a signal, the electromagnet pulls the contacts closed and sends line voltage to the compressor circuit. Over thousands of cycles the contacts pit, burn, and weld — the most common reason a condenser hums but won't start, chatters, or runs continuously even after the thermostat is satisfied. Replacing a worn contactor restores clean, reliable switching and protects the compressor from voltage drop and single-phasing damage.
| Spec | Value |
|---|---|
| Part Number | 1173690 |
| Type | Definite Purpose Contactor |
| Brand | ICP / Tempstar / Heil |
| Poles | 1 (Single-Pole) |
| Contact Rating | 40 Amps |
| Coil Voltage | 24 VAC |
| Fits Model | WPG4484090RKB1 |
Designed as the factory replacement for the ICP, Tempstar, Heil, and Comfortmaker WPG4484090RKB1 packaged gas/electric unit. Always confirm the amperage, pole count, and 24V coil rating against the contactor currently in your equipment before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.