Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for WPG4424090LKA1 — 1-Pole 30A 24V w/ Shunt | Ships Today
ICP

ICP Contactor for WPG4424090LKA1 — 1-Pole 30A 24V w/ Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite-purpose contactor (OEM #1172472) is a 1-pole, 30-amp device with a 24V coil and an integrated shunt, designed for your ICP WPG4424090LKA1 packaged gas/electric unit. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor and condenser fan motor. Pitted, welded, or burnt contacts are one of the most common no-cool failures — the unit may hum, chatter, or fail to start entirely.

Specifications

Spec Value
Part Number 1172472
Type Definite-Purpose Contactor (with shunt)
Brand ICP (Tempstar / Heil / Comfortmaker)
Poles 1-Pole
Contact Rating 30 A
Coil Voltage 24 V

Compatibility

Direct-fit replacement for the ICP WPG4424090LKA1 and comparable Tempstar, Heil, and Comfortmaker units calling for a 1-pole 30A 24V contactor with shunt. Verify pole count, amp rating, and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Label and disconnect the wires, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a cooling call with no chatter.

Signs You Need a Replacement

  • Buzzing, humming, or chattering from the contactor.
  • Pitted, blackened, or welded-together contacts.
  • Compressor and fan fail to start on a cooling call.
  • Coil does not pull the contacts in even with 24V present.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4424090LKA1 — 1-Pole 30A 24V w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4424090LKA1 — 1-Pole 30A 24V w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4424090LKA1 — 1-Pole 30A 24V w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online