Overview

This OEM contactor (part #1173690) is the high-voltage switch that powers the compressor and condenser fan in your ICP Tempstar Heil WPG3484130LKC1. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor; when the call ends, the contacts open. Rated at 40 amps with a single pole and a 24V coil, it handles the inrush and running load of the outdoor unit. Contactors wear out from millions of make/break cycles — pitted or welded contacts cause the unit to run nonstop or fail to start, and a chattering or buzzing contactor signals a weak coil.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Tempstar / Heil
Rating 40 Amps
Coil Voltage 24V
Poles 1

Compatibility

Built for the ICP Tempstar Heil WPG3484130LKC1 and other ICP-family condensing units using a 1-pole, 40A, 24V-coil contactor. Verify pole count, amp rating, and coil voltage match your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect line, load, and coil wires exactly per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and drop out when satisfied.

Signs You Need a Replacement

  • Compressor and fan won't start on a cooling call
  • Unit runs continuously and won't shut off (welded contacts)
  • Loud buzzing or chattering at the contactor
  • Visibly pitted, burned, or corroded contacts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3484130LKC1 — 1-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3484130LKC1 — 1-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3484130LKC1 — 1-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online