Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for WJA360000K000A1 — 1-Pole 40A 24V Coil | Ships Today
ICP

ICP Contactor for WJA360000K000A1 — 1-Pole 40A 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole definite purpose contactor (Part No. 1173690) is the electrical switch that energizes the compressor and condenser fan motor in your ICP WJA360000K000A1 unit. Rated at 40 amps with a 24-volt control coil, it closes when the thermostat calls for cooling and opens when the demand is met. Because the contacts arc on every cycle, contactors are among the most frequently replaced HVAC components. Telltale signs of failure include a humming or chattering outdoor unit, a condenser that won't start, burnt or pitted contacts, or a system that runs nonstop because the contacts have welded shut.

Specifications

Spec Value
Part Number 1173690
Type Single-Pole (1P) Definite Purpose Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Amp Rating 40A
Coil Voltage 24V
Poles 1
Fitment OEM Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP WJA360000K000A1 condensing unit. Also a correct replacement across Tempstar, Heil, and Comfortmaker equipment specifying a 1-pole 40A 24V contactor. Verify your existing part number and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and coil wires before disconnecting.
  4. Remove — Safely discharge the run capacitor, then transfer wires one at a time or label them as you remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start.
  • Visibly burnt, pitted, or welded contacts.
  • Chattering or rapid clicking on a cooling call.
  • Compressor runs continuously because contacts are fused closed.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WJA360000K000A1 — 1-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WJA360000K000A1 — 1-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WJA360000K000A1 — 1-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.