This OEM 1-pole definite purpose contactor (part number 1172472) is the main switching relay for the outdoor condensing unit on your ICP WJA342000K000A1 system. Rated at 30 amps with a 24-volt control coil and an integrated shunt, it energizes the compressor and condenser fan motor every time the thermostat calls for cooling. When the 24V coil is energized, its magnetic field pulls the contacts closed and completes the high-voltage circuit to the compressor. A worn contactor is one of the most common causes of a no-cooling call. Typical symptoms include a humming or buzzing outdoor unit that will not start, pitted or welded contacts that keep the compressor running continuously, chattering, or no response at all on a cooling call. Because the contacts arc on every cycle, this is a wear item that should be replaced as soon as pitting or burning appears to prevent a stuck-closed or open failure.
| Spec | Value |
|---|---|
| OEM Part Number | 1172472 |
| Type | 1-Pole Definite Purpose Contactor w/ Shunt |
| Brand | ICP / Tempstar / Heil |
| Contact Rating | 30 Amps |
| Coil Voltage | 24 VAC |
| Poles | 1 |
| Fits Model | WJA342000K000A1 |
This contactor is a direct OEM replacement for the ICP WJA342000K000A1 condensing unit and shares the same platform across many Tempstar, Heil, and Comfortmaker units of the same tonnage. Confirm the existing part number (1172472) and coil voltage before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.