This is the OEM single-pole, 30 amp definite-purpose contactor with shunt (part number 1172472) for the ICP / Heil / Tempstar WCH3494GKC100 heat pump. The contactor is the electrically operated switch that powers the outdoor unit: a 24-volt signal from the thermostat energizes the control coil, which pulls the 30A line contact closed and feeds line voltage to the compressor and condenser fan. The integrated shunt provides the second-pole electrical path used on single-pole designs. Contactors wear out from the constant arcing each time they open and close — when they fail, the outdoor unit hums without starting, runs continuously because the contacts have welded shut, or chatters and buzzes from a weak coil.

Specifications

Spec Value
OEM Part Number 1172472
Type Definite Purpose Contactor, 1-Pole w/ Shunt
Brand ICP / Heil / Tempstar
Current Rating 30 Amps
Poles 1
Coil Voltage 24V
Fits Model WCH3494GKC100

Compatibility

Direct OEM replacement for the WCH3494GKC100 heat pump and equivalent ICP-family units under Heil, Tempstar, Comfortmaker, and Arcoaire. Verify the 1-pole configuration, 30A contact rating, and 24V coil match your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical panel.
  3. Document — Photograph all line, load, shunt, and 24V coil connections before disconnecting.
  4. Remove — Label and disconnect each wire, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo.
  6. Test — Restore power and confirm the contact pulls in on a cooling/heating call and the compressor and fan energize.

Signs You Need a Replacement

  • Unit hums or buzzes but won't start
  • Welded contacts keep the compressor running nonstop
  • Chattering contactor from a failing coil
  • Burnt, pitted, or discolored contacts and terminals

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3494GKC100 — 1-Pole 30A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3494GKC100 — 1-Pole 30A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3494GKC100 — 1-Pole 30A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online