This genuine OEM single-pole contactor (part number 1172472) is the 30-amp, 24-volt-coil switching relay with shunt for the ICP WCA4484GKA100 condensing unit. The contactor is the electrically operated switch that closes the high-voltage circuit to the compressor and condenser fan whenever the thermostat calls for cooling. Over time the contact points pit, corrode, or weld from constant arcing, and the 24V coil can burn out. A failed contactor leaves the outdoor unit dead while the indoor blower still runs, or causes chattering, buzzing, and intermittent cooling. The integrated shunt provides the proper auxiliary connection used on these ICP platforms.

Specifications

Spec Value
Part Number 1172472
Type Definite-Purpose Contactor (with shunt)
Brand ICP
Poles 1-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Fits Model WCA4484GKA100

Compatibility

Factory-spec replacement for the ICP / Tempstar / Heil WCA4484GKA100 condensing unit. Verify pole count, contact amperage, and 24V coil rating against the part you are removing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer one wire at a time, or unbolt the old contactor and label leads as you remove them.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Outdoor unit is dead while the indoor blower still runs.
  • Loud buzzing, humming, or chattering at the contactor.
  • Visibly pitted, burned, or welded contacts.
  • Intermittent cooling that comes and goes with the contactor sticking.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCA4484GKA100 — 1-Pole 30A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCA4484GKA100 — 1-Pole 30A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCA4484GKA100 — 1-Pole 30A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online