Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for WCA3602AKN300 — 2-Pole 40A 24V Coil | Ships Today
ICP

ICP Contactor for WCA3602AKN300 — 2-Pole 40A 24V Coil | Ships Today

SKU: 1176763 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole, 40-amp definite purpose contactor (OEM part number 1176763) is built for the ICP/Tempstar/Heil WCA3602AKN300 air conditioning condensing unit. A contactor is the high-current relay that switches line voltage to the compressor and condenser fan motor each time the thermostat calls for cooling. The 24-volt control coil magnetically pulls the contacts together to complete that circuit. Repeated arcing slowly erodes the silver contact surfaces, producing resistance, heat, and voltage drop that can stress or stall the compressor. A fresh contactor restores reliable switching and prevents the nuisance no-cool calls that come from a tired, pitted part.

Specifications

Spec Value
OEM Part Number 1176763
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Resistive Rating 40 Amps
Coil Voltage 24 VAC
Application AC Compressor & Condenser Fan

Compatibility

A direct-fit replacement for the ICP/Tempstar/Heil WCA3602AKN300 condensing unit and other WCA-series equipment specifying the 1176763 contactor. Verify the 40A rating, 2-pole configuration, and 24V coil match your old part before installing.

Installation Guide

  1. Safety First — Shut off the disconnect and breaker, then confirm zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Take a clear photo of every wire connection before you begin.
  4. Remove — Mark and disconnect the line, load, and coil wires, then unscrew and remove the old contactor.
  5. Install — Mount the replacement and transfer each wire to the matching terminal using your photo as a guide.
  6. Test — Restore power, call for cooling, and verify the contacts close and the unit runs.

Signs You Need a Replacement

  • Buzzing or chattering from the condenser when the system engages.
  • Visible pitting, arcing scars, or melted plastic on the contactor.
  • Unit hums but the compressor and fan never start.
  • Stuck contacts that keep the system running after cooling is satisfied.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCA3602AKN300 — 2-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCA3602AKN300 — 2-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCA3602AKN300 — 2-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera