Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for WCA3304GKA2 — 1-Pole 30A 24V Coil w/Shunt | Ships Today
ICP

ICP Contactor for WCA3304GKA2 — 1-Pole 30A 24V Coil w/Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM definite-purpose contactor (part number 1172472) for the ICP / Tempstar / Heil WCA3304GKA2 condensing unit. A contactor is the electrically-controlled switch that powers your outdoor unit's compressor and condenser fan motor. When the thermostat calls for cooling, the 24-volt control circuit energizes the contactor coil, pulling the contacts closed to send line voltage to the compressor. This is a 1-pole, 30-amp unit with a 24V coil and an integrated shunt. As the contact points pit, arc, and burn over years of cycling, you'll see a humming unit that won't start, intermittent cooling, or a compressor that trips the breaker. Replacing a worn contactor is one of the most common and affordable HVAC repairs.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor, 1-Pole, w/Shunt
Brand ICP / Tempstar / Heil
Poles 1
Contact Rating 30 Amps
Coil Voltage 24V
Fits Model WCA3304GKA2

Compatibility

This contactor is the factory replacement for the ICP-family WCA3304GKA2 condensing unit and the many Tempstar, Heil, and Comfortmaker units built on the same platform that originally shipped with OEM part 1172472. Confirm your existing contactor is a 1-pole, 30A, 24V-coil unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage across the line terminals with a multimeter.
  2. Access — Remove the condenser service panel to expose the electrical compartment.
  3. Document — Photograph every wire on the old contactor before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo, confirming the 24V coil leads are correct.
  6. Test — Restore power, call for cooling, and verify the contacts pull in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums but the compressor and fan won't start.
  • Visible pitting, burning, or melted plastic on the contact points.
  • Intermittent cooling or contacts that chatter and buzz.
  • Contacts that weld closed, leaving the unit running constantly.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCA3304GKA2 — 1-Pole 30A 24V Coil w/Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCA3304GKA2 — 1-Pole 30A 24V Coil w/Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCA3304GKA2 — 1-Pole 30A 24V Coil w/Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online