Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RYMA75H001 — 3-Pole 30A 24V Coil | Ships Today
ICP

ICP Contactor for RYMA75H001 — 3-Pole 30A 24V Coil | Ships Today

SKU: 1054735 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM contactor for the ICP/Tempstar/Heil RYMA75H001 heat pump. The contactor is an electrically operated switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling or heating. This assembly covers the OEM options used on the unit: a 3-pole 30A contactor with a 24V coil (OEM 1070823 / 607339) and a 2-pole 20A 24V contactor (OEM 1054735). When the 24-volt coil is energized, the contacts close and pass line voltage to the compressor and fan. Pitted, burned, or chattering contacts are a leading cause of an outdoor unit failing to start.

Specifications

Spec Value
Part Numbers 1070823, 607339 (3P), 1054735 (2P)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 3-Pole (30A) / 2-Pole (20A)
Coil Voltage 24V
Rating 30 Amp / 20 Amp

Compatibility

Fits the ICP, Tempstar, Heil, and Comfortmaker RYMA75H001 heat pump and many related condensing units that use a 24V coil definite purpose contactor. Verify your existing contactor's pole count and amp rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph all wire positions before disconnecting.
  4. Remove — Note line/load and coil (24V) wire locations, disconnect them, and unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire to match your photo, confirming coil terminals receive 24V.
  6. Test — Restore power and verify the contacts pull in and the compressor/fan start on a call.

Signs You Need a Replacement

  • Outdoor unit hums but compressor/fan won't start
  • Pitted, burned, or melted contact points
  • Buzzing or chattering from the contactor
  • Contacts that stick closed and won't release

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RYMA75H001 — 3-Pole 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RYMA75H001 — 3-Pole 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RYMA75H001 — 3-Pole 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online