Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RYMA10H001 — 3-Pole 30A 24V Coil | Ships Today
ICP

ICP Contactor for RYMA10H001 — 3-Pole 30A 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor is the primary switching relay for the ICP Tempstar/Heil RYMA10H001 heat pump condensing unit. When the thermostat calls for cooling or heating, the 24V coil energizes and pulls the contacts closed, sending line voltage to the compressor and condenser fan motor. The RYMA10H001 platform uses several contactor configurations depending on production run — a 1-pole 25A (1050699), a 2-pole 20A (1054735), and a 3-pole 30A (1070823 / 607339). The 3-pole 30A 24V unit is the most common primary contactor. A failed contactor is one of the most frequent no-cool service calls: pitted or welded contacts, a chattering hum, or a burned-out coil all prevent the compressor from starting.

Specifications

Spec Value
OEM Part Numbers 1070823, 607339, 1054735, 1050699
Type Definite-purpose contactor
Brand ICP / Tempstar / Heil
Poles 3-pole (1, 2-pole variants available)
Contact Rating 30A
Coil Voltage 24V

Compatibility

Engineered for the ICP Tempstar Heil RYMA10H001 heat pump and shared across many International Comfort Products condensing units of the same generation. Confirm pole count and amp rating against the contactor currently installed before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line and load wiring plus the 24V coil leads before disconnecting.
  4. Remove — Note terminal positions, then transfer each wire one at a time; unscrew the old contactor from the mounting bracket.
  5. Install — Mount the new contactor, reconnect line, load, and 24V coil wires per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor starts.

Signs You Need a Replacement

  • Compressor and fan won't start but the coil reads 24V
  • Loud buzzing or chattering at the contactor
  • Pitted, blackened, or welded-shut contacts
  • Open or burned 24V coil on a multimeter test

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RYMA10H001 — 3-Pole 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RYMA10H001 — 3-Pole 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RYMA10H001 — 3-Pole 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online