Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RHS243S0AA0AAAA — 30A/40A/60A 24V Coil Options | Ships Today
ICP

ICP Contactor for RHS243S0AA0AAAA — 30A/40A/60A 24V Coil Options | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor for the ICP / Tempstar / Heil RHS243S0AA0AAAA heat pump is the high-voltage switch that energizes the compressor and condenser fan motor whenever the 24V control circuit calls for operation. Choose the rating that matches your unit: 2-pole 30A (part 1171554), 3-pole 40A (part 1172449), or 3-pole 60A (part 1183374) — all use a 24-volt coil. A failing contactor causes a unit that hums but won't start, chattering relays, welded/stuck contacts that won't shut off, or pitted, burned contacts that drop voltage to the compressor.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A), 1172449 (3P 40A), 1183374 (3P 60A)
Type Definite-Purpose Contactor (OEM)
Brand ICP / Tempstar / Heil
Coil Voltage 24V
Amp Ratings 30A / 40A / 60A
Poles 2-Pole / 3-Pole
Fits Model RHS243S0AA0AAAA
Application AC Compressor / Condenser Fan

Compatibility

Direct-fit for the ICP / Tempstar / Heil RHS243S0AA0AAAA heat pump. Match the pole count, amp rating, and 24V coil of your existing contactor before ordering. Backed by the National HVAC Parts fitment guarantee.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage on the line terminals with a multimeter.
  2. Access — Remove the condensing-unit service panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unbolt the old contactor from the bracket.
  5. Install — Mount the matching new contactor and reconnect every wire to the identical terminal per your photos.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor/fan start normally.

Signs You Need a Replacement

  • Unit hums but compressor/fan won't start
  • Contactor chatters or won't pull in on a call
  • Welded or stuck contacts that keep the unit running
  • Pitted, burned, or corroded contacts causing low voltage to the compressor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS243S0AA0AAAA — 30A/40A/60A 24V Coil Options | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS243S0AA0AAAA — 30A/40A/60A 24V Coil Options | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS243S0AA0AAAA — 30A/40A/60A 24V Coil Options | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online