Overview

This OEM contactor set for the ICP / Tempstar / Heil RHS240S0FA0AAAA includes the 2-pole 30-amp contactor (part 1171554) and the 3-pole 40-amp contactor (part 1172449), both with a 24V control coil. The contactor is the high-voltage switch that energizes the compressor and condenser fan motor when the thermostat sends a 24V call. Over time the contacts pit, burn, and weld together from arcing, causing the unit to run continuously, fail to start, or chatter loudly. Installing the correct OEM-rated contactor restores clean switching and protects the compressor from voltage drop and single-phasing.

Specifications

Spec Value
Part Numbers 1171554, 1172449
Type Definite Purpose Contactor
2-Pole Rating 30A (1171554)
3-Pole Rating 40A (1172449)
Coil Voltage 24V
Poles 2 / 3
Brand ICP (Tempstar / Heil)
Fits Model RHS240S0FA0AAAA
Fitment OEM / Direct Replacement

Compatibility

Built for the ICP RHS240S0FA0AAAA and related Tempstar, Heil, and Comfortmaker RHS240 units. Match the pole count, amperage, and 24V coil rating to your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect box and verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical service panel.
  3. Document — Photograph every line, load, and coil connection before disconnecting.
  4. Remove — Unfasten the old contactor from its mounting and transfer the wires one at a time.
  5. Install — Mount the new contactor and reconnect each lead to the matching terminal per your photo; verify the 24V coil leads.
  6. Test — Restore power and confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Compressor runs continuously or won't shut off
  • Loud buzzing or chattering at the contactor
  • Unit fails to start despite a 24V call at the coil

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS240S0FA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS240S0FA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS240S0FA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online