This OEM contactor set for the ICP RHS183S0BA0AAAA includes a 2-pole 30A contactor (part 1171554) and a 3-pole 40A contactor (part 1172449), both with a 24V control coil. A contactor is the electrically operated switch that delivers line-voltage power to the compressor and condenser fan motor when the 24V coil is energized by the thermostat. Pitted or burned contacts, a chattering coil, or contacts that weld closed are the most common failures. Symptoms include a system that won't start, a compressor that runs continuously, or an audible buzz from the control box.

Specifications

Spec Value
Part Numbers 1171554, 1172449
Type 2-Pole / 3-Pole Definite Purpose Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Rating 30A (2-pole), 40A (3-pole)
Coil Voltage 24V
Fit OEM

Compatibility

Designed for the ICP/Tempstar/Heil RHS183S0BA0AAAA and other ICP-family condensing units using a 24V-coil definite-purpose contactor. Confirm pole count and amp rating against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph every wire on the line and load sides before removing anything.
  4. Remove — Label and disconnect the leads, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan start.

Signs You Need a Replacement

  • System won't start or only starts intermittently
  • Buzzing or chattering from the contactor
  • Visibly pitted, burned, or welded contacts
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS183S0BA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS183S0BA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS183S0BA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online