This OEM definite-purpose contactor energizes the compressor and condenser fan motor in your ICP RHS183L0CA0AAAA heat pump. On a thermostat call, the 24-volt coil pulls the contacts closed, sending line voltage to the outdoor unit. Offered as a 2-pole 30-amp (OEM 1171554) or 3-pole 40-amp (OEM 1172449) device with a 24V coil, the contactor is among the highest-wear electrical parts in any condensing unit. Pitted or welded contacts cause hard starts, chattering, and intermittent cooling, while an open coil leaves the unit dead despite a calling thermostat. A fresh contactor restores reliable starting and protects the compressor from damaging voltage drops.

Specifications

Spec Value
OEM Part Numbers 1171554, 1172449
Type Definite Purpose Contactor
Poles 2-Pole / 3-Pole
Contact Rating 30A / 40A
Coil Voltage 24 VAC
Brand ICP / Heil / Tempstar

Compatibility

Built for the ICP RHS183L0CA0AAAA heat pump and shared across matching Heil, Tempstar, Comfortmaker, and Day & Night R-410A condensing units. Confirm pole count and amp rating against the contactor currently installed before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the terminals.
  2. Access — Remove the condenser service panel to expose the control compartment.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the unit starts.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan do not start.
  • Burned, pitted, or welded contacts.
  • Contactor chatters or will not pull in on a cooling call.
  • Intermittent cooling or repeated breaker trips.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS183L0CA0AAAA — 2-Pole 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS183L0CA0AAAA — 2-Pole 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS183L0CA0AAAA — 2-Pole 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online