This OEM contactor set for the ICP / Tempstar / Heil RHS183L0BA0AAAA heat pump covers both the 2-pole 30A contactor (part 1171554) and the 3-pole 40A contactor (part 1172449), each with a 24V coil. The contactor is the heavy-duty switch that closes when the thermostat calls for cooling or heating, sending line voltage to the compressor and condenser fan motor. Its contacts carry high current every cycle, so they pit, burn, and weld over time. A failing contactor causes a humming or chattering unit, a compressor that won't start, or one that won't shut off. Installing the correct OEM 24V-coil contactor restores reliable switching and protects the compressor.

Specifications

Spec Value
Part Numbers 1171554 (Contactor 2P 30A 24V), 1172449 (Contactor 3P 40A 24V)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole and 3-Pole options
Current Rating 30A (2P) / 40A (3P)
Coil Voltage 24V
Fits Model RHS183L0BA0AAAA

Compatibility

Designed for the ICP RHS183L0BA0AAAA outdoor heat pump and equivalent Tempstar, Heil, and Comfortmaker units. Match pole count (2P/3P), amp rating (30A/40A), and the 24V coil to your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label each, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect every wire to match your photos.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan start.

Signs You Need a Replacement

  • Loud humming or chattering from the outdoor unit.
  • Compressor won't start or won't shut off.
  • Pitted, burned, or welded contacts.
  • Coil won't pull the contactor in on a 24V call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS183L0BA0AAAA — 2-Pole 30A & 3-Pole 40A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS183L0BA0AAAA — 2-Pole 30A & 3-Pole 40A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS183L0BA0AAAA — 2-Pole 30A & 3-Pole 40A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.