Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RHS048L0CA0AAA — 2-Pole 30A 24V Coil | Ships Today
ICP

ICP Contactor for RHS048L0CA0AAA — 2-Pole 30A 24V Coil | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite purpose contactor (part 1178074) is the primary switching relay for the ICP/Tempstar/Heil RHS048L0CA0AAA heat pump. Its 24V control coil energizes when the thermostat calls for cooling or heating, pulling the contacts closed to deliver line voltage to the compressor and condenser fan motor. A failing contactor is one of the most common no-cool/no-heat service calls. Symptoms include pitted or welded contacts that keep the compressor running, a chattering or buzzing coil, or contacts that fail to close so the outdoor unit stays silent while the thermostat calls. The 30A rating and 24V coil match the factory specification, ensuring correct pull-in and reliable operation.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Fitment OEM

Compatibility

Engineered for the ICP/Tempstar/Heil RHS048L0CA0AAA heat pump and shares this contactor across many comparable ICP-family condensing units and heat pumps using a 2-pole 30A 24V control circuit. Always confirm the existing contactor's amp rating, pole count, and coil voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service/control panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Note terminal positions, transfer wires one at a time off the old contactor, then unbolt it from the bracket.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the coil pulls in and the compressor and fan energize on a call.

Signs You Need a Replacement

  • Outdoor unit hums but compressor/fan won't start
  • Pitted, burned, or welded contacts
  • Loud buzzing or chattering from the coil
  • Compressor keeps running after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS048L0CA0AAA — 2-Pole 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS048L0CA0AAA — 2-Pole 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS048L0CA0AAA — 2-Pole 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online