This genuine OEM 40-amp contactor (part 1176763) is the high-voltage switch that energizes the compressor and outdoor fan in the ICP / Heil / Tempstar RHH060K0XA0AAAA heat pump. When the thermostat calls, a 24V signal pulls in the contactor coil, the contacts close, and line voltage flows to the compressor. Rated at 40 amps, it is sized to handle the inrush and running load of the outdoor unit. Contactors are one of the most common HVAC failure points: the contacts arc and pit every time they close, and over years of cycling they can weld shut (compressor runs constantly), burn open (unit won't start), or develop a chattering coil. Ants and debris drawn to the energized coil are another frequent cause of a stuck or buzzing contactor. Replacing this wear part restores clean, positive switching and protects the more expensive compressor downstream.

Specifications

Spec Value
OEM Part Number 1176763
Type Definite-Purpose Contactor
Brand ICP / Heil / Tempstar
Rating 40 Amp
Coil Voltage 24 VAC
Application Heat Pump / Compressor

Compatibility

Direct-fit replacement for the ICP / Heil / Tempstar RHH060K0XA0AAAA heat pump and related International Comfort Products platform units (Heil, Tempstar, Comfortmaker, Arcoaire). Verify the original part number and pole configuration before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical access panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unbolt the old contactor from its bracket.
  5. Install — Mount the new 40A contactor and reconnect each lead to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor starts.

Signs You Need a Replacement

  • Outdoor unit won't start or only starts when tapped
  • Loud buzzing or chattering from the contactor
  • Pitted, blackened, or welded contacts
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH060K0XA0AAAA — 40A | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH060K0XA0AAAA — 40A | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH060K0XA0AAAA — 40A | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online