Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RGX048KEXA0AAA — 40 Amp 2-Pole 24V Coil | Ships Today
ICP

ICP Contactor for RGX048KEXA0AAA — 40 Amp 2-Pole 24V Coil | Ships Today

SKU: 1176763 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 40-amp, 2-pole definite purpose contactor (part number 1176763) is the exact replacement for the ICP Tempstar Heil RGX048KEXA0AAA system. A contactor is an electrically operated switch: a low-voltage 24V signal energizes the coil, which pulls the high-voltage contacts closed to power the blower, inducer, or condenser circuit. The contacts arc on every cycle, so over time they pit, burn, and can weld shut. Common failure signs include equipment that won't start, a loud buzzing or chattering at the contactor, contacts stuck closed so the unit runs nonstop, or visible burning and melted plastic. Rated at 40 amps with a 24-volt coil, this OEM contactor restores reliable, quiet switching to your equipment.

Specifications

Spec Value
OEM Part Number 1176763
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Current Rating 40 Amps
Coil Voltage 24V
Contact Rating up to 600V
Poles 2

Compatibility

Direct-fit OEM replacement for the ICP Tempstar Heil RGX048KEXA0AAA. The same 40A 2-pole 24V-coil platform is shared across many ICP-family units; always confirm amperage, pole count, and coil voltage against the contactor you are replacing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the control compartment.
  3. Document — Photograph all wire positions before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor.
  5. Install — Mount the new contactor and reconnect each wire exactly as photographed.
  6. Test — Restore power and confirm the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • Loud chattering or buzzing from the contactor
  • System fails to start or starts intermittently
  • Contacts welded closed, causing continuous operation
  • Visible pitting, burning, or melted contactor housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGX048KEXA0AAA — 40 Amp 2-Pole 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGX048KEXA0AAA — 40 Amp 2-Pole 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGX048KEXA0AAA — 40 Amp 2-Pole 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online