Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RGS243HRFA0AAAA – 2-Pole & 3-Pole 30A/40A/60A 24V | Ships Today
ICP

ICP Contactor for RGS243HRFA0AAAA – 2-Pole & 3-Pole 30A/40A/60A 24V | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

These are genuine OEM definite-purpose contactors for the ICP / Tempstar / Heil RGS243HRFA0AAAA platform, available in 2-pole 30A (1171554), 3-pole 40A (1172449), and 3-pole 60A (1183142) configurations, all with a 24-volt coil. The contactor is the electrical switch that energizes the compressor and condenser fan when the thermostat calls for cooling. Pitted, welded, or chattering contacts are a leading cause of no-cool service calls. Replacing with the correctly rated OEM contactor restores clean switching and protects the compressor from low-voltage and single-phasing damage.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A), 1172449 (3P 40A), 1183142 (3P 60A)
Type Definite-purpose contactor
Poles 2-pole / 3-pole
Amp Rating 30A / 40A / 60A
Coil Voltage 24 VAC
Brand ICP / Tempstar / Heil
Fit OEM Replacement

Compatibility

Fits the ICP RGS243HRFA0AAAA and shared Tempstar, Heil, Comfortmaker, and Day & Night systems. Select the pole count and amp rating that matches the contactor currently in your unit.

Installation Guide

  1. Safety First – Disconnect power and verify zero voltage with a multimeter.
  2. Access – Remove the electrical compartment service panel.
  3. Document – Photograph all line, load, and coil wiring before disconnecting.
  4. Remove – Detach the wires and unbolt the old contactor from the mounting rail.
  5. Install – Mount the matching contactor and reconnect each wire to the same terminal per your photo.
  6. Test – Restore power and confirm the contactor pulls in cleanly on a cooling call.

Signs You Need a Replacement

  • Compressor and condenser fan will not start on a cooling call
  • Loud buzzing, humming, or chattering at the contactor
  • Pitted, blackened, or welded contacts that stick closed
  • System short-cycles or trips the breaker

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243HRFA0AAAA – 2-Pole & 3-Pole 30A/40A/60A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243HRFA0AAAA – 2-Pole & 3-Pole 30A/40A/60A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243HRFA0AAAA – 2-Pole & 3-Pole 30A/40A/60A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.