Overview

This OEM contactor fits the ICP / Tempstar / Heil RGS243HFFA0AAAA system and is offered in the factory-spec ratings used on this platform: a 2-pole 30A 24V contactor (part 1171554), a 3-pole 40A 24V contactor (part 1172449), and a 3-pole 60A 24V contactor (part 1183142). A contactor is an electrically operated switch — when the 24V coil is energized by the control circuit, its contacts close to send line voltage to the compressor and condenser fan. Pitted, welded, or chattering contacts are a leading cause of a unit that won't start, trips breakers, or short-cycles. Match the amperage and pole count to your original part for an exact replacement.

Specifications

Spec Value
Part Numbers 1171554, 1172449, 1183142
Type Definite-purpose contactor
Brand ICP (Tempstar / Heil)
Poles 2-pole / 3-pole
Amperage 30A / 40A / 60A
Coil Voltage 24V
Fitment OEM exact-fit

Compatibility

Built for the ICP RGS243HFFA0AAAA and shared Tempstar, Heil, and Comfortmaker condensing units. Confirm pole count, amperage, and 24V coil against the original contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser or control access panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, then unfasten the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, place a call for cooling, and confirm the contacts pull in and the compressor and fan energize.

Signs You Need a Replacement

  • Unit won't start or hums without engaging
  • Buzzing or chattering at the contactor
  • Pitted, burnt, or welded contacts
  • Compressor short-cycles or trips the breaker

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243HFFA0AAAA — 2-Pole 30A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243HFFA0AAAA — 2-Pole 30A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243HFFA0AAAA — 2-Pole 30A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online