This OEM definite-purpose contactor switches high-voltage power to the compressor and condenser fan on the ICP RGS240HREA0AAAA. When the 24V control coil energizes, the contacts close and pass line voltage to the load; when the call for cooling ends, they open. Pitted, welded, or chattering contacts are the most common HVAC service failure — they cause the outdoor unit to fail to start, to buzz loudly, or to keep running after the thermostat is satisfied. This listing covers the OEM contactor options for the unit: 1171554 (2-Pole 30A), 1172449 (3-Pole 40A), and 1183142 (3-Pole 60A), all with a 24V coil.

Specifications

Spec Value
OEM Part Numbers 1171554 (2P 30A), 1172449 (3P 40A), 1183142 (3P 60A)
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2 / 3
Contact Rating 30A / 40A / 60A
Coil Voltage 24V
Application AC Compressor / Condenser Fan

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS240HREA0AAAA and related RGS240 chassis units. Match the pole count and amp rating of your existing contactor before ordering — confirm against the unit's model and serial label.

Installation Guide

  1. Safety First — Disconnect power at the breaker and outdoor disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel.
  3. Document — Photograph the line, load, and 24V coil wiring before disconnecting.
  4. Remove — Disconnect all leads and unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and transfer each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and release cleanly.

Signs You Need a Replacement

  • Outdoor unit won't start or hums without engaging
  • Pitted, burned, or welded contacts
  • Loud buzzing or chattering from the contactor
  • Compressor keeps running after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240HREA0AAAA — 2-Pole 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240HREA0AAAA — 2-Pole 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240HREA0AAAA — 2-Pole 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.