Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RGS214HDCP4BAAA — 30A 2-Pole & 40A 3-Pole 24V Coil | Ships Today
ICP

ICP Contactor for RGS214HDCP4BAAA — 30A 2-Pole & 40A 3-Pole 24V Coil | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor package fits the ICP (Heil / Tempstar / Comfortmaker) RGS214HDCP4BAAA system. A contactor is the high-amperage electromechanical switch that energizes the compressor and/or fan circuit when the 24V control signal calls for operation. Part 1171554 is a 2-pole 30A contactor and part 1172449 is a 3-pole 40A contactor — both use a 24-volt coil. When a contactor fails, the most common symptoms are a unit that won't start, chattering or buzzing at the relay, welded/pitted contacts that keep the system running continuously, or visible arcing and burn marks on the terminals.

Specifications

Spec Value
OEM Part Numbers 1171554, 1172449
Type 2-Pole & 3-Pole Definite Purpose Contactor
Brand ICP / Heil / Tempstar / Comfortmaker
Contact Rating 30A (2-pole) / 40A (3-pole)
Coil Voltage 24V
Poles 2 and 3

Compatibility

Directly fits the ICP RGS214HDCP4BAAA and shared-platform Heil, Tempstar, and Comfortmaker units that use the 1171554 or 1172449 contactor. Always confirm the part number stamped on your existing contactor and verify pole count and coil voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the unit disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the control compartment.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time, unscrew the mounting bracket, and lift out the old contactor.
  5. Install — Mount the matching new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and verify the contactor pulls in and the unit energizes cleanly.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Loud buzzing or chattering when energized
  • Compressor or fan won't start despite a 24V call
  • System runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS214HDCP4BAAA — 30A 2-Pole & 40A 3-Pole 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS214HDCP4BAAA — 30A 2-Pole & 40A 3-Pole 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS214HDCP4BAAA — 30A 2-Pole & 40A 3-Pole 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online