This genuine OEM 2-pole definite purpose contactor (part number 1171554) is the main switching relay for the ICP / Tempstar / Heil RGS210LDAA0AAAA system. When the 24V control circuit energizes the coil, the two power contacts close and feed line voltage to the compressor and condenser fan. Rated for 30 amps per pole with a 24-volt coil, this contactor cycles on every call for cooling and is a common wear item. Failure shows up as pitted or welded contacts that keep the equipment running, a coil that hums or chatters but never pulls the contacts in, or no operation at all despite a thermostat call. A new OEM contactor restores crisp, dependable switching and shields the compressor from voltage problems.
| Spec | Value |
|---|---|
| Part Number | 1171554 |
| Type | 2-Pole Definite Purpose Contactor |
| Brand | ICP (Tempstar / Heil) |
| Contact Rating | 30 Amps per pole |
| Coil Voltage | 24V |
| Fit | OEM Replacement |
Engineered as the factory contactor for the ICP / Tempstar / Heil RGS210LDAA0AAAA system and a direct replacement across ICP-family units that use a 30A 2-pole, 24V-coil contactor. Confirm pole count, amp rating, and coil voltage against the contactor you are removing before installing.