Overview

Genuine OEM definite-purpose contactor for the ICP/Tempstar/Heil RGS210HFCA0AAAA, available as a 2-pole 30A unit (part 1171554) or a 3-pole 40A unit (part 1172449), both with a 24VAC control coil. A contactor is the high-current switch that powers the compressor and condenser fan motor: when the thermostat calls for cooling, 24V energizes the coil and pulls the contacts closed to deliver line voltage to the loads. Pitted, welded, or chattering contacts are one of the most common no-cool service calls.

Specifications

Spec Value
2-Pole Part Number 1171554
2-Pole Rating 30A, 2-pole
3-Pole Part Number 1172449
3-Pole Rating 40A, 3-pole
Coil Voltage 24VAC
Type Definite-purpose contactor
Brand ICP

Compatibility

Fits the ICP/Tempstar/Heil RGS210HFCA0AAAA. Choose the pole count and amp rating that matches the contactor you are replacing — 2-pole 30A or 3-pole 40A — and confirm the coil is 24V before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the contactor.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unfasten the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan energize.

Signs You Need a Replacement

  • Compressor and condenser fan won't start on a cooling call.
  • Loud buzzing or chattering from the contactor.
  • Contacts welded closed — outdoor unit runs continuously.
  • Burnt, pitted, or melted contact points or housing.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS210HFCA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS210HFCA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS210HFCA0AAAA — 2-Pole 30A & 3-Pole 40A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online