Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor for RGS102STBA0AAA — 2-Pole 30A 24V Coil | Ships Today
ICP

ICP Contactor for RGS102STBA0AAA — 2-Pole 30A 24V Coil | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor (ICP part 1178074) is the electromagnetic switch that energizes the high-voltage load circuit in your ICP/Tempstar/Heil RGS102STBA0AAA system. A 24-volt control signal from the thermostat or control board pulls in the contactor coil, closing both poles to pass line voltage to the connected load. Pitted, burned, or chattering contacts are one of the most common HVAC service calls — failure symptoms include a unit that hums but won't start, intermittent operation, welded contacts that won't release, or visible arcing and burn marks on the terminals.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Poles 2
Contact Rating 30A
Coil Voltage 24V

Compatibility

Direct OEM fit for the ICP Tempstar Heil RGS102STBA0AAA and shared across many ICP-family furnaces and condensing units that use a 2-pole 30A 24V-coil contactor. Always confirm pole count, contact amperage, and coil voltage against the part you are removing.

Installation Guide

  1. Safety First — Disconnect power at the breaker/disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the service/control panel.
  3. Document — Photograph all wires and terminal positions before disconnecting.
  4. Remove — Note the line, load, and 24V coil leads, then transfer them one at a time from the old contactor or unmount and unwire fully.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and drops out cleanly.

Signs You Need a Replacement

  • Unit hums or buzzes but the load won't energize
  • Pitted, blackened, or welded contacts
  • Audible chattering or intermittent cycling
  • Visible arcing or burnt terminal insulation

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102STBA0AAA — 2-Pole 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102STBA0AAA — 2-Pole 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102STBA0AAA — 2-Pole 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online