Overview

This is a genuine OEM 40-amp definite-purpose contactor (part number 1176763) for the ICP/Heil/Tempstar RGX036KECA0AAA gas furnace and its associated switching circuit. A contactor is an electrically operated switch: a 24-volt control signal energizes the coil, the contacts close, and line voltage passes to the load; remove the signal and a spring snaps the contacts open. This 2-pole unit is rated for 40A per pole with a 24VAC coil. Repeated arcing slowly pits and burns the contacts until they weld closed or fail to make contact, and the coil itself can open with age — producing a system that hums but won't start, won't shut off, or chatters under load. A fresh OEM contactor restores crisp, dependable switching and protects the rest of the system from voltage drop and contact chatter.

Specifications

Spec Value
Part Number 1176763
Type Definite-Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Contact Rating 40 Amps
Poles 2-Pole
Coil Voltage 24 VAC
Fitment OEM Replacement

Compatibility

Built for the ICP/Heil/Tempstar RGX036KECA0AAA. OEM contactor 1176763 (40A, 2-pole, 24V coil) is shared across many ICP-family RGX, RGS, and N-series units — confirm the part number stamped on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the service panel to expose the control compartment.
  3. Document — Photograph every wire and terminal location before disconnecting anything.
  4. Remove — Identify line, load, and 24V coil leads, transfer wires one at a time, and unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo; confirm tight, fully seated terminals.
  6. Test — Restore power and verify the contactor pulls in cleanly on a call and drops out fully when satisfied.

Signs You Need a Replacement

  • Loud hum or buzz from the contactor but the system won't start
  • Pitted, blackened, or welded contacts (system won't shut off)
  • Chattering or rapid clicking when the coil energizes
  • No 24V pull-in even with a confirmed control signal present

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGX036KECA0AAA — 2-Pole 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGX036KECA0AAA — 2-Pole 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGX036KECA0AAA — 2-Pole 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.