Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor 2-Pole 40A 24V for YJ060GB1 — 24V Coil | Ships Today
ICP

ICP Contactor 2-Pole 40A 24V for YJ060GB1 — 24V Coil | Ships Today

SKU: YJ060GB1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole contactor (part number 1149653) is the heavy-duty switch that powers the compressor and condenser fan in your ICP/Heil/Tempstar YJ060GB1 condensing unit. Rated at 40 amps with a 24-volt control coil, it switches both legs of incoming line voltage when the thermostat calls for cooling. The double-pole design fully breaks power to the load on both sides for safer, cleaner switching. Over time the contacts pit, arc, and either weld closed or burn open — causing a unit that won't start, loud humming or chattering, or a compressor that runs continuously. Replacing a worn 40A contactor restores reliable operation and protects the costly compressor.

Specifications

Spec Value
Part Number 1149653
Type Definite Purpose Contactor, 2-Pole
Brand ICP (Heil / Tempstar / Comfortmaker)
Contact Rating 40 Amps
Coil Voltage 24 VAC
Poles 2
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar YJ060GB1 and matching condensing units originally equipped with part 1149653. Confirm your existing contactor's amp rating, pole count, and coil voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the control compartment.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan energize on a cooling call.

Signs You Need a Replacement

  • Unit hums or buzzes but won't start
  • Pitted, burnt, or welded contacts
  • Chattering or rapid clicking at the contactor
  • Compressor runs nonstop from stuck-closed contacts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ060GB1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ060GB1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ060GB1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online