Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor 2-Pole 30A & 3-Pole 40A 24V for RHS240L0FA0AAAA | Ships Today
ICP

ICP Contactor 2-Pole 30A & 3-Pole 40A 24V for RHS240L0FA0AAAA | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

These genuine OEM contactors for the ICP / Tempstar / Heil RHS240L0FA0AAAA heat pump include the 2-pole 30A unit (part 1171554) and the 3-pole 40A unit (part 1172449), both with a 24V control coil. A contactor is the electromechanical switch that closes the high-voltage circuit to the compressor and condenser fan whenever the thermostat calls for cooling or heating. Over thousands of cycles the contacts pit, burn, and weld, or the 24V coil burns open. When that happens the unit may fail to start, chatter loudly, or — in the case of welded contacts — run continuously and refuse to shut off.

Specifications

Spec Value
Part Number 1171554 / 1172449
Description Contactor 2P 30A 24V / Contactor 3P 40A 24V
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Poles 2-Pole and 3-Pole
Contact Rating 30A / 40A
Coil Voltage 24 VAC
Fits Model RHS240L0FA0AAAA

Compatibility

Fits the ICP RHS240L0FA0AAAA heat pump and the shared Tempstar, Heil, and Comfortmaker platforms using OEM parts 1171554 and 1172449. Match the pole count and amp rating of your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Label and detach all wires, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Loud chattering or buzzing when the unit tries to start
  • Pitted, burnt, or welded contacts visible on inspection
  • Unit runs continuously and won't shut off
  • Compressor and fan fail to energize on a cooling call

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS240L0FA0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS240L0FA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS240L0FA0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online