This genuine OEM single-pole contactor (part #1173690) is the high-voltage switch that powers the compressor and condenser fan in your ICP, Heil, or Tempstar WPA4604000RKA1 condensing unit. Rated for 40 amps with a 24V control coil, it closes when the thermostat calls for cooling and energizes the outdoor unit. Contactors are a common failure point: pitted or welded contacts, a chattering buzz, or a burned-out coil will leave the system unable to start. Replacing this wear item restores reliable switching and protects downstream components from voltage drop and arcing damage.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Heil / Tempstar
Amp Rating 40A
Coil Voltage 24V
Poles 1

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WPA4604000RKA1 condensing unit and other ICP-family outdoor units using a 40A single-pole, 24V-coil contactor. Always match the amp rating, pole count, and coil voltage of the original before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser unit's electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Disconnect each wire, then unscrew the old contactor from the mounting bracket.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit won't start or hums without engaging
  • Loud buzzing or chattering from the contactor
  • Visibly pitted, burned, or welded contacts
  • Open or burned 24V coil (no continuity)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPA4604000RKA1 — OEM 1173690 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPA4604000RKA1 — OEM 1173690 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPA4604000RKA1 — OEM 1173690 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.