Overview

This is a genuine OEM 1-pole definite purpose contactor (part #1172472) for the ICP/Heil/Tempstar WJH342000K000A1 heat pump. Rated for 30 amps with a 24-volt control coil and an integrated shunt, the contactor is the electrically-controlled switch that energizes the compressor and outdoor fan motor whenever the thermostat calls. The shunt maintains a circuit path to the run capacitor and crankcase heater even when the contacts are open. Contactors are a high-wear item — the contacts arc every cycle and eventually pit, burn, or weld, which leaves the outdoor unit humming without starting or running nonstop.

Specifications

Spec Value
Part Number 1172472
Type 1-Pole Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Contact Rating 30 Amps
Coil Voltage 24V
Poles 1
Feature Integrated Shunt

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar WJH342000K000A1 and related condensing units that use a single-pole 30A 24V contactor. Verify amp rating and coil voltage against the part you are removing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the service panel from the condenser unit.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Disconnect the line, load, coil, and shunt wires; unscrew the old contactor.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit hums but won't start.
  • Pitted, burned, or welded contacts on the old part.
  • Buzzing or chattering under load.
  • Unit runs continuously and won't shut off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WJH342000K000A1 — With Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WJH342000K000A1 — With Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WJH342000K000A1 — With Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online