Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor 1-Pole 25A 24V for YK018G — 24V Coil | Ships Today
ICP

ICP Contactor 1-Pole 25A 24V for YK018G — 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole contactor (part number 1050699) is the electromechanical switch that energizes the condenser fan and compressor circuits in your ICP/Heil/Tempstar YK018G heat pump. Rated at 25 amps with a 24-volt control coil, it closes when the thermostat calls for cooling and passes line voltage to the load. Over time the silver contacts pit, arc, and weld together or burn open — leading to a unit that won't start, a humming or chattering sound, or a compressor that runs continuously because the contacts have fused closed. Replacing a worn contactor is one of the most common HVAC service repairs and restores reliable, safe switching.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand ICP (Heil / Tempstar / Comfortmaker)
Contact Rating 25 Amps
Coil Voltage 24 VAC
Poles 1
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar YK018G and matching condensing units that originally shipped with part 1050699. Always confirm your existing contactor's amp rating, pole count, and coil voltage match before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the control compartment.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan energize on a cooling call.

Signs You Need a Replacement

  • Unit hums or buzzes but the compressor and fan won't start
  • Visibly pitted, burnt, or welded contacts
  • Chattering or rapid clicking at the contactor
  • Compressor runs nonstop because contacts are stuck closed

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YK018G — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YK018G — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YK018G — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online