Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Contactor 1-Pole 25A 24V for YG018GB1 — Single-Pole Definite Purpose | Ships Today
ICP

ICP Contactor 1-Pole 25A 24V for YG018GB1 — Single-Pole Definite Purpose | Ships Today

SKU: YG018GB1-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM single-pole definite-purpose contactor (part number 1050699) for the ICP/Tempstar/Heil YG018GB1 heat pump. Rated at 25 amps with a 24-volt control coil, this contactor is the electromechanical switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heat-pump operation. When the 24V coil is energized, the contacts close and pass line voltage to the compressor; when the call ends, the contacts open. Pitted, welded, or chattering contacts are one of the most common reasons a condensing unit fails to start, hums, or trips the breaker. Replacing a worn contactor is an inexpensive way to restore reliable operation.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Poles 1 (Single-Pole)
Contact Rating 25 Amps
Coil Voltage 24 VAC
Fits Model YG018GB1

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil YG018GB1 heat pump and other 1.5–3 ton ICP-family condensing units that use a 25A single-pole 24V contactor. Always confirm the part number on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit's electrical service panel.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and remove the line, load, and 24V coil wires, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and the compressor/fan energize.

Signs You Need a Replacement

  • Compressor hums but won't start, or won't start at all.
  • Visible pitting, burning, or melted plastic on the contacts.
  • Chattering or buzzing from the contactor when energized.
  • Contacts stick closed so the unit won't shut off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG018GB1 — Single-Pole Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG018GB1 — Single-Pole Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG018GB1 — Single-Pole Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online