This OEM 1-pole 25-amp definite purpose contactor (PN 1173689) for the ICP/Tempstar/Heil WPG3302040LKB1 uses a 24-volt control coil to switch line power to the compressor and condenser fan motor. When the thermostat calls for cooling, the 24V coil pulls in the contacts, energizing the high-voltage circuit. Contactors fail from pitted or welded contacts, a burned-out coil, or stuck chatter. Symptoms include a unit that won't start, a humming contactor that won't pull in, or a compressor that won't shut off. A 25A single-pole contactor is a high-wear consumable and a leading cause of no-cool service calls.

Specifications

Spec Value
Part Number 1173689
Type Definite Purpose Contactor, Single Pole
Brand ICP / Tempstar / Heil
Poles 1
Contact Rating 25 A
Coil Voltage 24 V

Compatibility

Direct-fit OEM replacement for the ICP/Tempstar/Heil WPG3302040LKB1 packaged unit and Heil-family systems specifying a 1-pole, 25A, 24V-coil contactor.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the contactor line terminals with a multimeter.
  2. Access — Remove the control/electrical service panel.
  3. Document — Photo all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and remove wires, then unscrew the old contactor from its mounting bracket.
  5. Install — Mount the new contactor, reconnect line, load, and coil wires per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the unit runs.

Signs You Need a Replacement

  • Loud chattering or humming when the system calls for cooling
  • Pitted, blackened, or welded contacts
  • Compressor won't start or won't shut off
  • 24V coil reads open on a multimeter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3302040LKB1 — Single Pole | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3302040LKB1 — Single Pole | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3302040LKB1 — Single Pole | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online