Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Condenser Fan Motor for WPH4304000RKA1 — 1/5 HP 810 RPM | Ships Today
ICP

ICP Condenser Fan Motor for WPH4304000RKA1 — 1/5 HP 810 RPM | Ships Today

SKU: WPH4304000RKA1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM condenser fan motor (part #1186359) spins the outdoor fan blade on the ICP/Tempstar/Heil WPH4304000RKA1 heat pump, pulling air across the condenser coil to reject heat. Rated at 1/5 HP and 810 RPM, it is the workhorse that keeps head pressure in check during cooling and supports defrost in heat-pump heating. When this motor fails, the outdoor coil can't shed heat — the compressor runs hot, trips on high pressure or overload, and cooling capacity collapses. A motor that runs slow, hot, or noisy is on borrowed time and should be replaced before it takes the compressor with it.

Specifications

Spec Value
OEM Part Number 1186359
Type Condenser Fan Motor
Brand ICP / Tempstar / Heil
Horsepower 1/5 HP
Speed 810 RPM
Application Outdoor / Condenser Fan

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WPH4304000RKA1 heat pump. Verify HP, RPM, rotation, shaft diameter, and run-capacitor MFD against your existing motor before installing, as outdoor motors are matched to fan-blade pitch and unit airflow.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the fan grille/top panel of the condensing unit.
  3. Document — Photograph the motor wiring, capacitor leads, and the fan blade's position on the shaft.
  4. Remove — Loosen the blade set screw, pull the blade, then unbolt the old motor from the bracket and disconnect leads.
  5. Install — Mount the new motor, reinstall the blade at the same shaft depth, and reconnect wiring and the run capacitor per your photo.
  6. Test — Restore power, call for cooling, and confirm the fan spins up to full speed in the correct direction.

Signs You Need a Replacement

  • Outdoor fan won't start or only spins when pushed
  • Unit trips on high-pressure/overload during cooling
  • Loud grinding, humming, or hot-bearing smell from the fan
  • Fan runs slow or intermittently

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPH4304000RKA1 — 1/5 HP 810 RPM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPH4304000RKA1 — 1/5 HP 810 RPM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPH4304000RKA1 — 1/5 HP 810 RPM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online