This OEM condenser fan motor (part number 1186359) is the factory-specified 1/5 HP, 810 RPM motor for the ICP / Tempstar / Heil WPG4484115RKB1 unit. The condenser fan motor drives the outdoor fan that pulls air across the condenser coil to reject heat from the refrigerant. When this motor fails, the system loses its ability to dissipate heat, leading to high head pressure, compressor overheating, and a complete loss of cooling. This genuine OEM replacement matches the original horsepower and speed for correct airflow and long service life.

Specifications

Spec Value
OEM Part Number 1186359
Type Condenser Fan Motor
Horsepower 1/5 HP
Speed 810 RPM
Brand ICP / Tempstar / Heil
Fits Model WPG4484115RKB1
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil WPG4484115RKB1 package unit. Verify the horsepower, RPM, rotation, shaft diameter, and voltage match your existing motor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage and discharge the run capacitor before working.
  2. Access — Remove the top grille/fan assembly and the electrical service panel.
  3. Document — Photograph all motor and capacitor wiring and the fan blade position on the shaft.
  4. Remove — Loosen the blade set screw, pull the blade, then unbolt the old motor from the mount.
  5. Install — Mount the new motor, reinstall the blade at the same height, and reconnect wiring per your photo.
  6. Test — Restore power, call for cooling, and confirm the fan spins the correct direction at full speed.

Signs You Need a Replacement

  • Outdoor fan won't spin or starts only with a push
  • Motor hums, overheats, or trips the breaker
  • High head pressure or compressor short-cycling on heat
  • Worn, noisy, or seized motor bearings

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4484115RKB1 — 1/5 HP 810 RPM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4484115RKB1 — 1/5 HP 810 RPM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4484115RKB1 — 1/5 HP 810 RPM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.