Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Condenser Fan Motor 1/5 HP for WPG4364090LKA1 — 825 RPM | Ships Today
ICP

ICP Condenser Fan Motor 1/5 HP for WPG4364090LKA1 — 825 RPM | Ships Today

SKU: WPG4364090LKA1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 1/5 HP condenser fan motor (OEM Part No. 1186359, "MOTOR CND 1/5 HP") for the ICP / Tempstar / Heil WPG4364090LKA1 packaged unit. The condenser fan motor spins the outdoor fan blade that pulls air across the condenser coil, rejecting the heat the system absorbs from inside the home. Without adequate condenser airflow, head pressure climbs, the compressor overheats, and cooling capacity collapses. This motor is rated at 1/5 horsepower and is the direct factory replacement for the outdoor fan position. Condenser fan motors fail from worn bearings, overheating, and electrical breakdown of the windings — often accelerated by years of outdoor exposure to heat, dust, and moisture. A failed condenser fan motor is one of the most common warm-weather service calls: the compressor may run while the fan sits still, quickly driving the unit into a high-pressure trip. Typical symptoms include a fan that hums but won't turn, a blade that spins freely by hand but not under power, a motor that is hot to the touch and cuts out on thermal overload, and grinding or screeching bearing noise.

Specifications

Spec Value
OEM Part Number 1186359
Type Condenser (Outdoor) Fan Motor
Brand ICP / Tempstar / Heil
Horsepower 1/5 HP
Approx. Speed 825 RPM
Application Condenser Fan
Fits Model WPG4364090LKA1

Compatibility

This 1/5 HP condenser fan motor is the factory-specified outdoor fan motor for the ICP / Tempstar / Heil WPG4364090LKA1 packaged unit and is shared across many ICP-family condensing and packaged units of similar capacity. Confirm horsepower, rotation, shaft diameter, and voltage match your existing motor before installing, and reuse the correct run capacitor for the new motor.

Installation Guide

  1. Safety First — Disconnect power at the unit and breaker, then verify zero voltage at the motor leads with a multimeter.
  2. Access — Remove the top fan grille/panel to reach the motor and blade.
  3. Document — Photograph the wiring, blade position on the shaft, and motor orientation before disassembly.
  4. Remove — Loosen the blade set screw and pull the blade, disconnect the motor leads, and unbolt the motor from its mount.
  5. Install — Mount the new motor in the same orientation, transfer the blade at the same shaft depth, and reconnect the leads and capacitor per your photo.
  6. Test — Restore power, start a cooling call, and confirm the fan spins up to full speed in the correct direction with no wobble or noise.

Signs You Need a Replacement

  • Outdoor fan hums but the blade won't spin (with a good capacitor).
  • Motor runs hot and shuts off on thermal overload, then restarts when cool.
  • Grinding, screeching, or rumbling bearing noise from the fan.
  • Compressor runs but the unit trips on high pressure because the fan is dead.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4364090LKA1 — 825 RPM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4364090LKA1 — 825 RPM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4364090LKA1 — 825 RPM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online