This OEM 1/5 HP condenser fan motor (part number 1186447) drives the outdoor fan that pulls air across the condenser coil on your ICP/Tempstar/Heil WCH3362GKR500. Moving air across the coil is what lets the system reject heat — a seized or failed fan motor causes the compressor to overheat, trip on high pressure, and short-cycle. Replacing the motor restores proper airflow and protects the compressor from heat-related failure.

Specifications

Spec Value
Part Number 1186447
Type Condenser Fan Motor
Brand ICP / Tempstar / Heil
Horsepower 1/5 HP
Application Condenser Fan
Fit OEM Direct Replacement

Compatibility

Direct factory replacement for the ICP WCH3362GKR500 condensing unit and other ICP-family units originally equipped with the 1/5 HP condenser fan motor (part 1186447). Verify horsepower, rotation, shaft diameter, and mounting before installing.

Installation Guide

  1. Safety First – Disconnect power and verify zero voltage with a multimeter.
  2. Access – Remove the top fan grille/shroud to free the motor and blade assembly.
  3. Document – Photograph the wiring, capacitor leads, and blade position/depth on the shaft before disassembly.
  4. Remove – Loosen the blade set screw, pull the blade, unbolt the motor from the bracket, and disconnect the leads.
  5. Install – Mount the new motor, transfer the blade to the same depth and orientation, and reconnect wiring per your photos.
  6. Test – Restore power and confirm the fan spins up in the correct direction at full speed.

Signs You Need a Replacement

  • Outdoor fan won't spin or only starts after a manual push.
  • Motor runs hot, grinds, or has noisy/rough bearings.
  • Compressor trips on high head pressure on hot days.
  • Motor hums but the blade stays still.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WCH3362GKR500 – OEM 1186447 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WCH3362GKR500 – OEM 1186447 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WCH3362GKR500 – OEM 1186447 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.