Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower Run Capacitor 7.5 MFD 370V for RGS243SDAA0AAAA — Ships Today
ICP

ICP Blower Run Capacitor 7.5 MFD 370V for RGS243SDAA0AAAA — Ships Today

SKU: 1183001-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM run capacitor (part number 1183001, "Capacitor Plate") for the ICP RGS243SDAA0AAAA gas furnace. The run capacitor provides the continuous phase shift the blower motor needs to maintain torque and run efficiently. Rated at 7.5 MFD and 370 volts, it stores and releases energy on each AC cycle to keep the indoor blower motor spinning smoothly. When a run capacitor weakens or fails, the motor draws excess current, overheats, hums, struggles to start, or stops entirely — leaving you with no airflow and a furnace that locks out on a limit fault.

Specifications

Spec Value
Part Number 1183001
Type Single Run Capacitor
Brand ICP (Tempstar / Heil / Comfortmaker)
Capacitance 7.5 MFD
Voltage 370V (440V compatible)
Application Furnace Blower Motor

Compatibility

Engineered as a direct-fit replacement for the ICP RGS243SDAA0AAAA furnace and other ICP-family (Tempstar, Heil, Comfortmaker) models using the same blower assembly. Always confirm the MFD and voltage rating stamped on your existing capacitor before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Capacitors hold a charge — discharge across the terminals with an insulated resistor before touching.
  2. Access — Remove the furnace blower service panel.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Note terminal markings, pull the spade connectors, and unfasten the old capacitor from its mounting strap.
  5. Install — Mount the new capacitor and reconnect each wire exactly as photographed.
  6. Test — Restore power and confirm the blower starts promptly and runs without humming.

Signs You Need a Replacement

  • Blower motor hums but will not start spinning
  • Bulged, leaking, or swollen capacitor top
  • Weak or intermittent airflow from registers
  • Furnace trips on high-limit due to poor air movement

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my ICP RGS243SDAA0AAAA — Ships Today?
Yes. This is the factory-specified OEM capacitor for the ICP RGS243SDAA0AAAA — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my ICP RGS243SDAA0AAAA — Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online