Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower Motor Module for WAPT304A2 — 1/3 HP 230V | Ships Today
ICP

ICP Blower Motor Module for WAPT304A2 — 1/3 HP 230V | Ships Today

SKU: 1190331-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM blower motor module (ICP part #1190331, also supplied as blower motor #1185023) is the 1/3 HP, 230V air-moving motor for the ICP / Tempstar / Heil WAPT304A2 system. The blower motor drives the indoor air handler or furnace blower wheel, circulating conditioned air through the duct system on both heating and cooling cycles. When this motor weakens or fails you will notice reduced airflow, longer run times, overheating limit trips, or a complete loss of indoor air circulation. Bearing wear, a failed run capacitor, or burned windings are the most common causes of failure. Replacing the motor with a genuine OEM 1/3 HP 230V unit restores rated airflow and protects the rest of the system from heat and pressure problems caused by low air movement.

Specifications

Spec Value
Part Number 1190331 / 1185023
Type Blower Motor Module
Brand ICP (Tempstar / Heil)
Horsepower 1/3 HP
Voltage 230V
Application Furnace blower / air handler

Compatibility

Engineered as a direct-fit replacement for the ICP / Tempstar / Heil WAPT304A2 air handler. Always verify the part number on your existing motor and confirm horsepower, voltage, and rotation before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all wire connections and the blower wheel set-screw position before disconnecting.
  4. Remove — Loosen the wheel set screw, disconnect leads, unbolt the motor from the blower housing and slide it out.
  5. Install — Mount the new motor, reset the wheel position, and reconnect every lead exactly per your photos.
  6. Test — Restore power and confirm smooth start-up, correct rotation, and full airflow.

Signs You Need a Replacement

  • Weak or no airflow from the supply registers.
  • Motor hums but will not start, or starts slowly.
  • Overheating that trips the limit switch and short-cycles the system.
  • Grinding, squealing, or rattling bearing noise.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAPT304A2 — 1/3 HP 230V | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAPT304A2 — 1/3 HP 230V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAPT304A2 — 1/3 HP 230V | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online