Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower Motor Module for WAPL244A2 — 1/3 HP 230V | Ships Today
ICP

ICP Blower Motor Module for WAPL244A2 — 1/3 HP 230V | Ships Today

SKU: 1190332 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 1/3 HP, 230V blower motor module for the ICP/Tempstar/Heil WAPL244A2 air handler. It covers OEM part numbers 1190332 (Motor Module 1/3 HP 230V) and 1185024 (Blower Motor 1/3 HP). The blower motor drives the indoor air handler wheel that circulates conditioned air through your duct system on both heating and cooling cycles. A failing blower motor causes weak airflow, no airflow, overheating and tripping on the limit switch, loud bearing or humming noise, or a motor that buzzes but never spins. Worn bearings, an open winding, or a failed module are the usual culprits.

Specifications

Spec Value
Part Numbers 1190332, 1185024
Type Blower / Air Handler Motor Module
Brand ICP / Tempstar / Heil
Horsepower 1/3 HP
Voltage 230V
Fit OEM Replacement

Compatibility

Built as a direct OEM replacement for the ICP/Tempstar/Heil WAPL244A2 air handler. The 1190332 module and 1185024 blower motor are interchangeable 1/3 HP 230V service parts for this model and related ICP-family air handlers using the same blower assembly. Confirm horsepower, voltage, rotation, and shaft size against your existing motor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before servicing.
  2. Access — Remove the air handler service panel and slide out the blower assembly.
  3. Document — Photograph all motor wiring, the capacitor leads, and the blower wheel position on the shaft.
  4. Remove — Disconnect the wiring, loosen the wheel set screw, pull the wheel, and unbolt the old motor from the blower housing.
  5. Install — Mount the new motor, reinstall the blower wheel at the same depth, tighten the set screw on the shaft flat, and reconnect wiring per your photo.
  6. Test — Restore power and verify the blower spins freely, ramps to speed, and moves proper airflow.

Signs You Need a Replacement

  • Weak airflow or no airflow from the supply registers
  • Motor hums or buzzes but will not start
  • Loud grinding, squealing, or bearing noise from the blower
  • System overheats and trips on the high-limit switch

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAPL244A2 — 1/3 HP 230V | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAPL244A2 — 1/3 HP 230V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAPL244A2 — 1/3 HP 230V | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online