Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower Motor Module 1/3 HP 230V for WAPL304A3 — Direct OEM Fit | Ships Today
ICP

ICP Blower Motor Module 1/3 HP 230V for WAPL304A3 — Direct OEM Fit | Ships Today

SKU: 1190331 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 1/3 HP, 230V blower motor module (OEM part numbers 1190331 and 1185023) for the ICP/Tempstar/Heil WAPL304A3 air handler. The blower motor is the heart of your air distribution system — it spins the indoor blower wheel to move conditioned air through your ductwork. As an ECM-style motor module, it delivers efficient, variable airflow for both heating and cooling modes. When this motor fails you will typically notice weak or no airflow at the registers, the system running but no air moving, unusual humming or grinding noises, the motor overheating and tripping on thermal overload, or the blower failing to start at all. Replacing it with the correct OEM module restores rated airflow and protects the rest of your system from strain.

Specifications

Spec Value
Part Number 1190331 / 1185023
Type Blower Motor Module
Brand ICP (Tempstar / Heil)
Horsepower 1/3 HP
Voltage 230V
Application Furnace Blower / Air Handler
Fitment OEM — Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP WAPL304A3 air handler and equivalent Tempstar, Heil, and Comfortmaker units that share this blower assembly. Always confirm your model and OEM part number (1190331 or 1185023) before ordering to guarantee fitment.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the air handler service/blower panel.
  3. Document — Photograph every wire and connector position before disconnecting.
  4. Remove — Disconnect the motor harness, loosen the blower wheel set screw, slide the blower assembly out, and unbolt the failed motor module from the housing.
  5. Install — Mount the new motor module, reinstall the blower wheel and set screw, slide the assembly back in, and reconnect all wiring exactly per your photo.
  6. Test — Restore power and verify the blower starts, ramps, and moves air at the registers in both heat and cool modes.

Signs You Need a Replacement

  • Little or no airflow from the supply registers
  • Blower hums but won't start or repeatedly trips on overload
  • Grinding, squealing, or loud bearing noise from the air handler
  • Motor runs hot, smells of burnt insulation, or cycles intermittently

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAPL304A3 — Direct OEM Fit | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAPL304A3 — Direct OEM Fit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAPL304A3 — Direct OEM Fit | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online