Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower Motor for WPG4304060LKA1 — 1/2 HP X-13 ECM | Ships Today
ICP

ICP Blower Motor for WPG4304060LKA1 — 1/2 HP X-13 ECM | Ships Today

SKU: 1186863-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 1/2 HP X-13 blower motor (part number 1186863) for the ICP/Tempstar/Heil WPG4304060LKA1 packaged gas unit. The X-13 is a constant-torque ECM (electronically commutated motor) that drives the indoor blower wheel, moving conditioned air through the supply ductwork. Unlike older PSC motors, the X-13 maintains a programmed torque across changing static pressure, delivering quieter operation and lower electrical draw. Common failure symptoms include the blower failing to start, intermittent operation, overheating and thermal cutout, unusual humming or grinding, or weak airflow that triggers high-limit lockouts on the furnace.

Specifications

Spec Value
Part Number 1186863
Type X-13 Constant-Torque ECM Blower Motor
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Application Indoor Furnace / Air Handler Blower
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP/Tempstar/Heil WPG4304060LKA1 model. Always verify the motor part number (1186863), horsepower, and motor module/programming against your existing unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and unit disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph the motor module wiring and blower wheel position before disconnecting.
  4. Remove — Disconnect the motor harness and module, loosen the blower wheel set screw, pull the wheel, then unbolt the old motor from the housing.
  5. Install — Mount the new motor, reinstall the blower wheel with proper set-screw torque, reattach the module, and reconnect per your photo.
  6. Test — Restore power and verify the blower ramps and runs at the correct speed taps.

Signs You Need a Replacement

  • Blower won't start or starts intermittently
  • Motor runs hot and shuts off on thermal overload
  • Grinding, humming, or rattling from the blower section
  • Weak airflow causing furnace high-limit trips

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4304060LKA1 — 1/2 HP X-13 ECM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4304060LKA1 — 1/2 HP X-13 ECM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4304060LKA1 — 1/2 HP X-13 ECM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online