Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower Motor for WPG4244060LKB1 — OEM 1/2 HP Furnace Blower | Ships Today
ICP

ICP Blower Motor for WPG4244060LKB1 — OEM 1/2 HP Furnace Blower | Ships Today

SKU: 1188128-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 1/2 HP blower motor (part #1188128) is the indoor air-mover for the ICP WPG4244060LKB1 packaged gas-electric unit. The blower motor drives the squirrel-cage wheel that pushes conditioned air through the heat exchanger and evaporator coil and out to the supply ductwork. Rated at 1/2 horsepower, it provides the airflow your system needs for both heating and cooling operation. A failing blower motor causes weak airflow, overheating lockouts, or a complete loss of circulation, and is a frequent cause of furnace high-limit trips and frozen coils.

Specifications

Spec Value
Part Number 1188128
Type Blower Motor (Indoor)
Brand ICP
Horsepower 1/2 HP
Application Furnace / Air Handler Blower

Compatibility

Direct factory replacement for the ICP / Tempstar / Heil WPG4244060LKB1 packaged unit's indoor blower assembly. Also fits related ICP-family units specifying a 1/2 HP blower motor — confirm shaft size, rotation, and mounting against your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel and slide out the blower assembly.
  3. Document — Photograph all motor wiring, capacitor leads, and the blower wheel position on the shaft.
  4. Remove — Disconnect the motor leads, loosen the wheel set-screw, pull the wheel, and unbolt the old motor from the housing.
  5. Install — Mount the new motor, set the blower wheel to the same shaft depth, tighten the set-screw, and reconnect wiring per your photo.
  6. Test — Restore power and verify the blower spins freely, ramps to speed, and moves strong airflow.

Signs You Need a Replacement

  • Weak or no airflow from the supply registers
  • Motor hums but won't start, or runs hot and shuts down
  • Loud grinding, squealing, or rattling bearing noise
  • Furnace high-limit trips or evaporator coil freezes from low airflow

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4244060LKB1 — OEM 1/2 HP Furnace Blower | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4244060LKB1 — OEM 1/2 HP Furnace Blower | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4244060LKB1 — OEM 1/2 HP Furnace Blower | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online