Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower Motor for WFEL045A036A1 — 1/3 HP OEM Replacement | Ships Today
ICP

ICP Blower Motor for WFEL045A036A1 — 1/3 HP OEM Replacement | Ships Today

SKU: 1187055-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This 1/3 HP blower motor (OEM part number 1187055) is the factory replacement for the ICP/Tempstar/Heil WFEL045A036A1 air handler. The blower motor drives the indoor fan wheel that circulates conditioned air through your ductwork on both heating and cooling cycles. When a blower motor fails, the system may run with no airflow, trip the limit switch from overheating, or fail to start at all. Common failure modes include worn bearings (humming or grinding noise), an open winding, or a shorted motor that repeatedly trips the breaker. This is a genuine OEM-spec direct-drive motor rated at 1/3 horsepower to match the original equipment.

Specifications

Spec Value
Part Number 1187055
Type Blower / Direct-Drive Motor
Brand ICP (Tempstar / Heil)
Horsepower 1/3 HP
Application Furnace blower / Air handler
Fits Model WFEL045A036A1

Compatibility

Engineered as the OEM replacement for the ICP/Tempstar/Heil WFEL045A036A1 air handler. Always confirm the horsepower, voltage, rotation, and shaft size against your existing motor before installing. This listing is the factory-matched blower motor for that model.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all wire connections and the blower wheel position on the shaft before disconnecting anything.
  4. Remove — Disconnect the motor leads, loosen the blower wheel set screw, pull the wheel, then unbolt the motor from the blower housing band.
  5. Install — Mount the new motor, slide the blower wheel back to its documented depth, tighten the set screw on the shaft flat, and reconnect the leads per your photo.
  6. Test — Restore power and verify the blower starts, spins the correct direction, and delivers full airflow.

Signs You Need a Replacement

  • No airflow from registers while the system calls for heat or cool
  • Loud humming, grinding, or squealing from the blower compartment
  • Motor hot to the touch or cycling on its internal overload
  • Breaker trips when the blower is energized

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WFEL045A036A1 — 1/3 HP OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WFEL045A036A1 — 1/3 HP OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WFEL045A036A1 — 1/3 HP OEM Replacement | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online