Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Blower & Condenser Fan Motors for WPG4424090LKB1 — 1/2 HP & 1/5 HP | Ships Today
ICP

ICP Blower & Condenser Fan Motors for WPG4424090LKB1 — 1/2 HP & 1/5 HP | Ships Today

SKU: WPG4424090LKB1-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This listing covers the genuine OEM fan motors for the ICP / Tempstar / Heil WPG4424090LKB1 package unit: the 1/2 HP blower motor (part number 1188130) that moves conditioned air through the supply ductwork, and the 1/5 HP, 810 RPM condenser fan motor (part number 1186359) that pulls air across the outdoor coil to reject heat. The blower motor drives the indoor airflow for both heating and cooling, while the condenser motor keeps head pressure in check during the cooling cycle. A failing motor typically shows up as overheating and thermal-cutout cycling, loud bearing noise, or a motor that hums but will not spin — leading to weak airflow, frozen coils, or high-pressure trips.

Specifications

Spec Value
Blower Motor Part Number 1188130
Blower Motor Rating 1/2 HP
Condenser Motor Part Number 1186359
Condenser Motor Rating 1/5 HP, 810 RPM
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the WPG4424090LKB1 package gas/electric unit and related ICP, Tempstar, Heil, and Comfortmaker models using these motors. Confirm HP, RPM, voltage, rotation, and shaft size against your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the appropriate service panel for the blower or condenser section.
  3. Document — Photograph all motor wiring, capacitor leads, and blade or wheel position.
  4. Remove — Mark the blade/wheel position on the shaft, loosen the set screw, slide off the wheel, and unbolt the old motor.
  5. Install — Mount the new motor, transfer the blade or blower wheel to the same shaft depth, and reconnect wiring per your photo.
  6. Test — Restore power, run the system, and confirm correct rotation, smooth operation, and proper airflow.

Signs You Need a Replacement

  • Motor hums but will not start or spin
  • Loud grinding, squealing, or worn bearings
  • Motor runs hot and cycles on its thermal overload
  • Weak airflow, frozen indoor coil, or high-pressure trips

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4424090LKB1 — 1/2 HP & 1/5 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4424090LKB1 — 1/2 HP & 1/5 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4424090LKB1 — 1/2 HP & 1/5 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online